目 錄
章 概述······························································2
1.1 產品介紹···························································2
1.2 使用范圍···························································2
1.3 性能參數···························································2
1.4 外部結構···························································2
二章 使用······························································3
2.1 驗收·······························································3
2.2 工作環境···························································3
2.3 儀器組裝···························································3
2.4 使用方法···························································3
2.5 觀測位置和條件·····················································3
三章 基本原理··························································4
3.1 基本原理··························································4
四章 讀數與統計························································5
4.1 觀測方法與頻率·····················································5
4.2 計算·······························································5
4.3 結束·······························································5
五章 儀器保養··························································6
六章 保修期····························································6
章 概述
1.1 產品介紹
AD-LB林格曼煙氣濃度圖是種按煙氣的視覺黑度對煙氣進行監測的方法。由于很難定煙氣的視覺黑度與其中有害物質含量之間的精對應關系,因此這種方法不能替代煙氣排放濃度的實際測定。但由于這方法簡易便行,成本低廉,故在許多國家被列為常用的煙氣排放監測方法之。實踐證明,對于燃煤煙氣之類,煙氣濃度圖不失為種有用的監測手段。
1.2 使用范圍
該儀器廣泛應用于各地的環境保護部門、環境監測部門、各工礦企業及各大院校的煙氣黑度測定工作及研究。通過對煙氣黑度的測定,可以分析煙氣排放對空氣的污染程度及燃料的燃燒利用率,從而為環境管理和節約能源提供有效的監測手段。
1.3 性能參數
AD-LB林格曼黑度等O~5;外形尺寸:100×27×0.5cm(高×寬×厚);每等林格曼圖尺寸:21×14cm(寬×高)
1.4 外部結構
1.41 濃度板:100cm*27cm可放置在三腳架上使用亦可手持使用。
1.42 三腳架:固定濃度板,可調節高度。
二章 使用
2.1 驗收
2.11 核對儀器的備件和附件與裝箱單是否相符。
2.12 如有損壞或缺件請立即與我們聯系。
2.2 工作環境
2.2.1 儀器應在干燥、清潔場所使用和保存。
2.2.2 避免灰塵,潮濕和腐蝕性氣體。
2.2.3 避免雨天使用。
2.2.4 使用溫度范圍:-15~+35℃。
2.2.5 相對濕度:≤80V0。
2.3 儀器組裝
2.3.1 從包裝箱內取出林格曼煙氣濃度圖和支架。
2.3.2 取出三腳架并支起,將兩個卡槽固定在支架主體上,調節主體的旋鈕,然后調節高度,將濃度圖板放入上下兩個卡槽內,調節到適當高度后,旋緊支架主體的旋鈕固定。
2.4 使用方法
2.4.1 觀察,將安裝好的林格曼煙氣濃度圖及其三腳架放置在平坦且平穩無風的位置。使用時圖面上不能加任何覆蓋層,以免削弱圖面的照明。如圖面被弄臟或褪色,應立即換掉,以免影響觀察精度。
2.5 觀測位置和條件
2.51 應在白天進行觀測,放置三腳架時應使圖面面向觀察者。應盡可能使圖位于觀察者 至煙囪頂部的連線上,并使圖與煙氣有相似的天空背景。圖距觀察者應有足夠的距 離以使圖上的線條看起來似乎消失,從而使每個方塊有均勻的黑度。對于絕大多數 觀察者這距離約為15米以上。
2.52 觀察時應將剛離開煙囪的煙的黑度與圖上的黑度進行比較,記下煙氣的林格曼數
及這種黑度的煙持續排放的時間。如煙氣黑度處于兩個林格曼之間,可估計個
1/2或1/4林格曼數。
2.53 觀察煙氣力求在比較均勻的天空光照下進行。如果在太陽光照射下觀察,應盡量使
照射光線與視線成直角,排氣的流向與觀測者視線垂直。光線不應來自觀察者的
方或后方。白色的方塊提供個有關照明的指標,用于發現圖上任何遮陰、照明不
均勻及雨斑或別的污點。如在陰霾的情況下觀察,由于天空背景較暗,在讀數時應
根據經驗取稍偏低的數。
2.54 觀察煙氣的仰視角應盡可能低。應盡量避免在過于陡峭的角度下觀察。
三章 基本原理
3.1 基本原理
林格曼煙氣濃度圖是19世紀末法國的林格曼先提出的。他利用比色原理,將排放源出口處煙氣顏色與某標準濃度物進行比較的測定方法,當某排氣顏色與標準濃度物的顏色相接近時,就認為煙塵濃度與標準濃度物的濃度相致。林格曼圖有多種形式,常用的標準形式是由14X21cm的6個不同黑度的小塊組成,除全白與全黑分別代表林格曼黑度0和5外,其余4個別是根據黑色條格占整塊面積的百分數來定的、黑色條格的面積占20%為1,占40%為2,占60%為3,占80%為4,林格曼排氣濃度圖見(圖3.1)。
(圖3.1)
四章 讀數與統計
4.1 觀測方法與頻率
根據中華人民共和國環境保護行業標準 HJ/T 398-2007 固定污染源排放煙氣黑度
的測定林格曼煙氣黑度圖法規定:
4.11 觀察時,將煙囪排出煙氣的黑度與林格曼煙氣黑度圖進行比較,記下煙氣的林格曼數。如煙氣黑度處于兩個林格曼之間,可估計個0.5或0.25林格曼數。如在陰天的情況下觀察,由于天空背景較暗,在讀數時應根據經驗取稍偏低的數(減去0.25 或0.5 )。
4.12 每分鐘觀測4次,觀察者不宜直盯著煙氣觀測,而應看幾鐘然后停幾鐘,每次觀測(包括觀看和間歇時間)約15,連續觀測煙氣黑度的時間不少于30分鐘。每次觀測15記錄個讀數,連續觀測煙氣黑度的時間30分鐘,記錄120次觀測讀數,對于煙氣排放穩定的污染源,可減少觀測頻次,每分鐘觀測2次,記錄60個讀數。
4.2 計算
4.21 按林格曼黑度別將觀測值分,分別統計每黑度別出現的累計次數和時間。
4.22 除了在觀測過程中出現5林格曼黑度時,煙氣黑度按5計,不必繼續觀測外,其它情況都必須連續觀測30分鐘。分別統計每黑度別出現的累計時間,煙氣黑度按30分鐘內出現累計時間超過2分鐘的大林格曼黑度計。
4.23 按以下順序和原則定煙氣黑度別:
4.24 林格曼黑度5:30分鐘內出現5林格曼黑度時,煙氣的林格曼黑度按5計。
4.25 林格曼黑度4:30分鐘內出現4及以上林格曼黑度的累計時間超過2分鐘時,煙氣的林格曼黑度按4計。
4.26 林格曼黑度3:30分鐘內出現3及以上林格曼黑度的累計時間超過2分鐘時,煙氣的林格曼黑度按3計。
4.27 林格曼黑度2:30分鐘內出現2及以上林格曼黑度的累計時間超過2分鐘時,煙氣的林格曼黑度按2計。
4.28 林格曼黑度1:30分鐘內出現1及以上林格曼黑度的累計時間超過2分鐘時,煙氣的林格曼黑度按1計。
4.29 林格曼黑度<1:30分鐘內出現小于1林格曼黑度的累計時間超過28分鐘時,煙氣的林格曼黑度按<1 計。
五章 儀器保養
4.1 維護及保養
4.11 盡量不要使污漬觸碰表面,灰塵可用洗耳球吹氣或干凈毛筆及潔凈軟布拭去。
4.12 在霉雨季節或長期不用時,可放入干燥容器并及時更換干燥劑,以免產霉變。
六章 保修期
5.1 保修期
5.11 從購買產品之日起,產品除人為原因損壞可以得到1年的保修及維護服務。
原創作者:北京愛歐德儀器設備有限公司